RCML 20192 _ Detector Coupling Tester
RCML20192 detector coupling tester is used for coupling production and testing of various pin-position ROSA/BOSA devices of APD and PIN-TIA (Vpd/Mon).
This instrument comes with a light attenuation module, which can achieve rapid attenuation. There is a built-in high-precision optical power meter for output monitoring, which can monitor the optical power of the output port in real time during attenuation. It also supports external optical module interfaces and can be connected to different wavelength modules to provide different coupling light source requirements for the production of ROSA/BOSA devices.
Features
- Customized test conditions can meet various test requirements. It is compatible with two types of detectors, APD and PIN-TIA (Vpd/Mon), and supports devices with different pin packages.
- Provides four built-in light sources of 850nm, 1310nm, 1490nm and 1550nm, which can output analog modulation frequencies in the range of 1M, 2M and 4M.
- Built-in light attenuation module.
- Supports SFP and QSFP assembly optical modules
- Outputs 0~70V continuously adjustable voltage.
- Response current measurement range 0~9mA.
- There are protection circuits against overshoot, kickback, ESD and surge.
- Support return loss test (optional).
Technical Specifications
APD Coupling
Item Spec. Breakdown Voltage (Vbr) 0~70V, Accuracy 0.1%FS±0.07V Dark Current (Id) Measuring range:0~100nA,Accuracy 1%FS±1nA Response Current (Iapd) Measuring range:
Range 1: 0~1000nA, Accuracy 0.1%FS±1nA
Range 2: 0~10uA, Accuracy 0.1%FS±10nA
Range 3: 0~100uA, Accuracy 0.1%FS±0.1uA
Range 4: 0~1000uA, Accuracy 0.1%FS±1uA
Range 5: 0~9000uA, Accuracy 0.1%FS±9uAPerformance indicators detected during APD coupling. PIN-TIA(Mon) Coupling
Item Spec. Dark Current (Id) Measuring range:0~240nA,Accuracy 1%FS±2.4nA Response Current (Imon) Measuring range:
Range 1: 0~2400nA, Accuracy 0.1%FS±2.4nA
Range 2: 0~24uA, Accuracy 0.1%FS±24nA
Range 3: 0~240uA, Accuracy 0.1%FS±0.24uA
Range 4: 0~2400uA, Accuracy 0.1%FS±2.4uA
Range 5: 0~9000uA, Accuracy 0.1%FS±9uAPerformance indicators detected during PIN-TIA(Mon) coupling. Other Performance Indicators
Item Spec. TIA Voltage
(Vcc-TIA)Output voltage:0~5V, Accuracy 0.1%FS±20mV TIA Current
(Icc)Measuring range:0~100mA, Accuracy 0.1%FS±1mA Signal Reception Strength
(D+、D–)Range:0~3.3V, Accuracy 1%FS±2mV Return Loss Measuring range:10~50dB, Accuracy ±0.3db External Light Source Interface Supports SFP and QSFP assembly optical modules Calibration Wavelength 1310nm、1490nm、1550nm,
[Note] Other wavelengths can be customized.Attenuation Range 0~40dB Attenuation Accuracy ≤±0.2dB
Typical Data
EOS Test
Optional Items
Return Loss Function
Item Spec. #1 Not support return loss #2 Support loss recovery