PRECISE|Comprehensive Tester|LIV 60301

LIV 6 Series LIV Comprehensive Tester

LIV60301 comprehensive tester is suitable for LIV characteristic curve, PV characteristic curve and characteristic parameter testing of LD, TO-Can, and TOSA, EML and butterfly devices with TEC function in the optical communication industry, also can support spectral characteristic testing (an external spectrometer is required).

系統集溫控器、電流源、電壓源、電流表、電壓表和光功率計等功能於一體。

Features

  • Supports pulse spectrum testing.
  • Support multi-mode TOSA in 50um and 62.5um optical fiber transmission comparison.
  • FP / DFB / VCSEL / DML / EML / SOA-EML devices in any assembly type
  • Supports LD Reverse Leakage Current Test
  • LD Reverse Vbr Test
  • Supports MPD Dark Current Test
  • Support LIV Scanning, Step time 2ms~6s optionally configured
  • Supports PV curve test of EA and DC-ER test.
  • EA Reverse Vbr Test
  • Support TEC temperature control
  • Max. Support 5 channel driving current and 1 channel driving voltage simultaneously.
  • Provides three light source input ports: built-in PIN, external PIN interface and integrating sphere interface.
  • Built-in PIN response wavelength range: 800~1700nm.

Technical Specifications

ItemSpec.
Laser Assembly TypeFP / DFB / VCSEL / DML / EML / SOA-EML devices in any assembly type
Test ItemsLIV curve,PV curve,Ith,Po,Vf,Im,Rs,SE,Kink,Vinf,DC-ER, etc.
LD Drive Current OutputRange:0~250mA,Accuracy 0.1%FS±0.25mA,max. customizable to 500mA
LD Forward Voltage TestRange:0~5.0V,Accuracy 0.1% FS±50mV
LD Reverse Leakage Current Test0~100nA,Accuracy 1% FS±1.0nA,@<50%RH
0~1uA,Accuracy 0.1% FS±10nA,@<50%RH
0~10uA,Accuracy 0.1% FS±0.1uA,@<50%RH
0~100uA,Accuracy 0.1% FS±1uA,@<50%RH
0~1mA,Accuracy 0.1% FS±10uA,@<50%RH
LD Backward Voltage OutputRange:0~30.0V,Accuracy 0.1% FS±0.3V
LD Reverse Current Output0~10uA,Accuracy 0.1% FS±0.1uA
0~100uA,Accuracy 0.1% FS±1uA
0~1mA,Accuracy 0.1% FS±10uA
LD Reverse Vbr TestRange:0~30.0V,Accuracy 0.1% FS±0.3V
MPD Backward Voltage OutputRange:0~5.0V,Accuracy 0.1% FS±50mV
MPD Dark Current TestRange:0~300nA,Accuracy 0.5% FS±3.0nA,@<50%RH
MPD Backlight Current TestRange:0~3000uA,Accuracy 0.1% FS±10uA
Four-channel Extended Current OutputRange:0~250mA,Accuracy 0.1%FS±0.25mA,max. customizable to 500mA
Four-channel Extended Current and Voltage Drop TestRange:0~5.0V,Accuracy 0.1% FS±50mV
Built-in PIN Tube Detects Optical PowerRange:0~10mW,Accuracy 0.1% FS±50uW
[Note]For higher power testing, please choose: external PIN tube or integrating sphere
Built-in PIN Tube Response Wavelength800~1700nm (Supports 850nm VCSEL device testing)
Correction FunctionUsers can self-calibrate power, voltage, and backlight.
LIV Scanning TimeScanning step 0.1~10.0mA configurable,
Step time 2ms~6s optionally configured
PV Scanning TimeScanning step 0.02V~0.1V configurable,
Step time 2ms~6s optionally configured
Pulse Spectrum TestPulse width 200us~650ms,period 2ms~6s,, synchronous output trigger signal
EV Voltage OutputRange:-5.0V ~ +5.0V,Accuracy 0.1% FS±50mV
EV Dark Current TestRange:0 ~ 1mA,Accuracy 0.1% FS±10uA
EV Current TestRange:-200mA ~ +200mA,Accuracy 0.1% FS±2mA
TEC VoltageRange:-1.6V~+1.6V,Accuracy 1% FS±50mV
TEC CurrentRange:-1A~+1A,Accuracy 1% FS±10mA
ThermistorNTC,10K@25℃
Temperature ControlRange:-40℃~+100℃,Accuracy ±0.15℃
Temperature SpeedTypical value 5s (25℃~45℃)

TOP

en_USEnglish