DEVISER|Opto-electrical Testing Analysis|AE8595T

AE8595T High Performance Optical Spectrum Analyzer

AE8595T is a diffraction grating spectrum analyzer for optical fiber signal spectrum analysis. It operates in the wavelength range of 600 to 1700nm, with a max. resolution of 30pm, a max. measurement power of +23dBm, and a power sensitivity as low as -90dBm.

It can be used for semiconductor laser (DFB, FP) spectrum characteristic measurement, WDM system testing, EDFA system parameter testing, transmittance and drift testing.

Features

  • Spectral range 600nm~1700nm, suitable for single-mode and multi-mode fiber input.
  • 7 wavelength resolution settings from 30pm to 2nm, users can select the best value based on testing requirements.
  • Sensitivity settings as low as -90dBm.
  • 74dB large dynamic range, capable of effectively separating similar spectral signals and performing precise measurements.
  • ±0.015nm high wavelength accuracy, built-in wavelength calibration function.
  • High noise light suppression rate, monochromator design can provide excellent stray light suppression capability.
  • Rich functional options such as WDM, light source, EDFA, etc.
  • Data interface supports Ethernet, USB, GP-IB, etc.
  • Build automated inspection and testing systems based on customer requirements.

Application

EDFA Performance Measurement

  • PSSE:Spontaneous radiation power of the light source
  • PASE:EDFA amplified spontaneous emission power
  • Gain
  • Noise Factor

DFB Light Source Measurement

  • Central wavelength
  • Center wavelength power and total power bandwidth
  • Bandwidth
  • SMSR:Side Mode Suppression Ratio
  • OSNR:Signal-to-Noise Ratio
  • Central wavelength shift

WDM Channel Measurements

  • Channel wavelength and power
  • Channel Offset
  • OSNR:In-band and out-of-band signal-to-noise ratio
  • Bandwidth

FP Light Source Measurement

  • Central wavelength
  • RMS Width vs. FWHM
  • Power
  • Bandwidth
  • Mode Interval

Gas Detection & Concentration Measurement

  • When used with a broadband light source such as a Super-Continuum (SC) or Super-radiant Light-emitting Diode (SLD),the AE8595T can display the optical absorption spectrum of the measured gas mixture.

Notch Bandwidth Measurement

  • E8595T measures the passband bandwidth or stopband bandwidth from the measurement waveform of V-characteristic or U-characteristic filter through notch bandwidth measurement.

Function

Measurement

Measurement ModeCW light、Pulsed light、Air/Vacuum wavelength
Scan ModeRepeat、Single、Automatic setting、Scan between line markers
Conditional SettingCentral wavelength、 Span、Number of sampling points、Wavelength resolution、Sensitivity
Double speed mode、Smoothing、APC power compensation

Display

Vertical Axis ScalePower scale (0.1~10dB/div., linear)、Power auxiliary scale (0.1~10dB/div., linear)、Reference power、Partitions (8, 10, 12)、Power spectrum width (dB/nm)、dB/km、%、Noise shielding
Horizontal Axis ScaleWavelength (nm)、Frequency (THz)、Waveform Zoom
Display Mode & Project Normal display、Split screen display、Data table、Label、Template、Measurement conditions

Curve

Curve Function 7 independent curves、Max./Min. value hold、Calculation between curves、Standardized display、Curve fitting、Peak curve fitting、Marker curve fitting、Rolling average (2~100 times)
OthersCurve copy/Clear function、Write/Fix setting、Display/Blank setting

Mark & Search

Mark Triangle mark (Max.1024)、Vertical/Horizontal line mark、Advanced mark
SearchPeak、Valley、Next Peak、Next Valley、Multiple Peaks、Multiple Valleys、Auto Search (On/OFF)、Search between horizontal markers、Search zoom area

Data Analysis

Analysis Function Spectral width (Threshold、Envelope、RMS、Peak-RMS、Notch)、WDM (OSNR) Analysis、EDFA-NF analysis、Filter peak/Trough analysis、WDM filter peak/Trough analysis、DFB-LD/FP-LD/LED analysis、SMSR analysis、Power analysis、PMD analysis
OthersAutomatic analysis (ON/OFF)、Analysis between horizontal line markers、Analysis within zoom area

Other Function

Wavelength CalibrationAutomatic wavelength calibration with built-in wavelength reference source

Instrument Size

Unit:mm / [ inch ]

Technical Specifications

Spectral Measurement

Input FiberSM (9.5 / 125μm)
MMF (50 / 125μm、62.5 / 125μm)
Wavelength Range600 ~ 1700nm
Resolution Bandwidth0.03 ~ 2nm
Resolution Setting0.03nm、0.05nm、0.1nm、0.2nm、0.5nm、1nm、2nm
Wavelength Accuracy1520 to 1620nm ±0.015nm
1450 to 1520nm ±0.025nm
Full Range ±0.08nm
Wavelength Repeatability±0.01nm (1 minute)
Wavelength Linearity±0.015nm (1520 to 1580nm)
±0.025nm (1450 to 1520nm, 1580 to 1620nm)
Min. Sampling Resolution0.001nm

Power Measurement

Power Sensitivity-90dBm (1300-1620nm, Resolution ≧ 0.05nm)
-85dBm (1000-1300nm,Resolution ≧ 0.05nm)
-55dBm (600-1000nm,Resolution ≧ 0.05nm)
Max. Input Power+23dBm
Power Accuracy±0.3dB (1310 / 1550nm,Input power:-20dBm)
Power Linearity±0.08dB (Input power:-50 ~ +10dBm)
Max. Number of Sampling50001
Optical Return Loss35dB (Using APC interface)
Polarization Dependence±0.08dB (1550nm)
Optical Dynamic RangePeak wavelength ±0.1nm 45dB (Resolution:0.03nm)
Peak wavelength ±0.4nm 70dB (Resolution:0.05nm)
Peak wavelength ±1.0nm 74dB (Resolution:0.05nm)
Pulse Testing ConditionsPulse width ≥10ns,Pulse frequency ≥10kHz

Technical specification

Display10.1in 1280×800 capacitive touch screen
InterfaceUSB2.0 ×5,USB 3.0,VGA,GP-IB
Ethernet (10M/100M/1000M), RS232-DB9
Power SupplyAC parameters 100~240V 1.7A 50~60Hz
Factory Installed Options Optical input interface adapter FC/SC optional
GP-IB Interface
Built-in calibrated light source
FC SC