LIV 6 Series LIV Comprehensive Tester
LIV60301 comprehensive tester is suitable for LIV characteristic curve, PV characteristic curve and characteristic parameter testing of LD, TO-Can, and TOSA, EML and butterfly devices with TEC function in the optical communication industry, also can support spectral characteristic testing (an external spectrometer is required).
The system integrates the functions of temperature controller, current source, voltage source, ammeter, voltmeter and optical power meter.
Features
- Supports pulse spectrum testing.
- Support multi-mode TOSA in 50um and 62.5um optical fiber transmission comparison.
- FP / DFB / VCSEL / DML / EML / SOA-EML devices in any assembly type
- Supports LD Reverse Leakage Current Test
- LD Reverse Vbr Test
- Supports MPD Dark Current Test
- Support LIV Scanning, Step time 2ms~6s optionally configured
- Supports PV curve test of EA and DC-ER test.
- EA Reverse Vbr Test
- Support TEC temperature control
- Max. Support 5 channel driving current and 1 channel driving voltage simultaneously.
- Provides three light source input ports: built-in PIN, external PIN interface and integrating sphere interface.
- Built-in PIN response wavelength range: 800~1700nm.
Technical Specifications
Item Spec. Laser Assembly Type FP / DFB / VCSEL / DML / EML / SOA-EML devices in any assembly type Test Items LIV curve,PV curve,Ith,Po,Vf,Im,Rs,SE,Kink,Vinf,DC-ER, etc. LD Drive Current Output Range:0~250mA,Accuracy 0.1%FS±0.25mA,max. customizable to 500mA LD Forward Voltage Test Range:0~5.0V,Accuracy 0.1% FS±50mV LD Reverse Leakage Current Test 0~100nA,Accuracy 1% FS±1.0nA,@<50%RH
0~1uA,Accuracy 0.1% FS±10nA,@<50%RH
0~10uA,Accuracy 0.1% FS±0.1uA,@<50%RH
0~100uA,Accuracy 0.1% FS±1uA,@<50%RH
0~1mA,Accuracy 0.1% FS±10uA,@<50%RHLD Backward Voltage Output Range:0~30.0V,Accuracy 0.1% FS±0.3V LD Reverse Current Output 0~10uA,Accuracy 0.1% FS±0.1uA
0~100uA,Accuracy 0.1% FS±1uA
0~1mA,Accuracy 0.1% FS±10uALD Reverse Vbr Test Range:0~30.0V,Accuracy 0.1% FS±0.3V MPD Backward Voltage Output Range:0~5.0V,Accuracy 0.1% FS±50mV MPD Dark Current Test Range:0~300nA,Accuracy 0.5% FS±3.0nA,@<50%RH MPD Backlight Current Test Range:0~3000uA,Accuracy 0.1% FS±10uA Four-channel Extended Current Output Range:0~250mA,Accuracy 0.1%FS±0.25mA,max. customizable to 500mA Four-channel Extended Current and Voltage Drop Test Range:0~5.0V,Accuracy 0.1% FS±50mV Built-in PIN Tube Detects Optical Power Range:0~10mW,Accuracy 0.1% FS±50uW
[Note]For higher power testing, please choose: external PIN tube or integrating sphereBuilt-in PIN Tube Response Wavelength 800~1700nm (Supports 850nm VCSEL device testing) Correction Function Users can self-calibrate power, voltage, and backlight. LIV Scanning Time Scanning step 0.1~10.0mA configurable,
Step time 2ms~6s optionally configuredPV Scanning Time Scanning step 0.02V~0.1V configurable,
Step time 2ms~6s optionally configuredPulse Spectrum Test Pulse width 200us~650ms,period 2ms~6s,, synchronous output trigger signal EV Voltage Output Range:-5.0V ~ +5.0V,Accuracy 0.1% FS±50mV EV Dark Current Test Range:0 ~ 1mA,Accuracy 0.1% FS±10uA EV Current Test Range:-200mA ~ +200mA,Accuracy 0.1% FS±2mA TEC Voltage Range:-1.6V~+1.6V,Accuracy 1% FS±50mV TEC Current Range:-1A~+1A,Accuracy 1% FS±10mA Thermistor NTC,10K@25℃ Temperature Control Range:-40℃~+100℃,Accuracy ±0.15℃ Temperature Speed Typical value 5s (25℃~45℃)